Gas sampling device - Company Ranking(3 companyies in total)
Last Updated: Aggregation Period:〜
This ranking is based on the number of page views on our site.
Display Company Information
Company Name | Featured Products | ||
---|---|---|---|
Product Image, Product Name, Price Range | overview | Application/Performance example | |
![]() Automatic Gas Sampling Device GSP-311FT (Intrinsic Safety Explosion-Proof Structure)
100,000 yen-500,000 yen |
<Specifications> Instantaneous flow measurement range: 0 to 250 mL/min Setting modes: Timer mode (automatic suction stop at set time, cumulative flow display) Fixed volume mode (automatic suction stop at set volume, suction time display) Power supply: Alkaline dry batteries, AA size x 2 Continuous use: Approximately 5 hours (above 20°C) External dimensions: 80(W) x 40(D) x 140(H) mm Weight: 300g (including batteries) ◆For details, please refer to the catalog. | Please make use of it for daily work environment management and air quality measurement in homes, schools, and offices. | |
![]() Automatic Gas Collection Device GSP-500FT
100,000 yen-500,000 yen |
<Specifications> - Setting Modes Timer Mode: Automatic stop at set time (1 minute to 30 hours) Fixed Volume Mode: Automatic stop at set volume (0.01 to 900L) - Flow Rate Range Timer Mode: 50 to 500 mL/min Fixed Volume Mode: 10 to 500 mL/min (For 10 to 49 mL/min, intermittent sampling at a suction flow rate of 50 mL/min) - Power Supply Two AA alkaline batteries or nickel-hydride batteries Dedicated lithium-ion rechargeable battery (optional) - Continuous Usage Time AA alkaline batteries: Approximately 20 hours (200 mL/min, 2 kPa, 25°C) Lithium-ion rechargeable battery (optional): Approximately 90 hours (200 mL/min, 2 kPa, 25°C) - Dimensions Approximately 80(W) × 40(D) × 126(H) mm - Weight Approximately 280g (including batteries) ◆ For more details, please refer to the catalog. | Please use it for daily work environment management and air quality measurement in homes, schools, and offices. | |
![]() Automatic Gas Collection Device GSP-400FT
100,000 yen-500,000 yen |
<Specifications> Set flow rate range: 50–1000 mL/min Set mode: (Timer mode) automatically stops at set time, cumulative flow display (Fixed volume mode) automatically stops at set volume, suction time display Instantaneous and cumulative flow accuracy: 100–1000 mL/min: ±5% RD (±3% RD when calibrated) 50–99 mL/min: ±5 mL/min (not supported for specified calibration) Operating temperature and humidity range: (Temperature) 0–40°C (Humidity) 10–90% RH (without condensation) Power supply: 4 AA alkaline batteries or nickel-hydride batteries Continuous usage time: approximately 10 hours (1000 mL/min, no load at 20°C or above) AC power (using AC adapter), external battery (optional) External dimensions: approximately 150(W) × 75(D) × 100(H) mm Weight: approximately 500g (including batteries) ◆ For details, please refer to the catalog. | It is for sampling harmful air pollutants. | |
---
--- |
--- |
-
- Featured Products
-
Automatic Gas Sampling Device GSP-311FT (Intrinsic Safety Explosion-Proof Structure)
- overview
- <Specifications> Instantaneous flow measurement range: 0 to 250 mL/min Setting modes: Timer mode (automatic suction stop at set time, cumulative flow display) Fixed volume mode (automatic suction stop at set volume, suction time display) Power supply: Alkaline dry batteries, AA size x 2 Continuous use: Approximately 5 hours (above 20°C) External dimensions: 80(W) x 40(D) x 140(H) mm Weight: 300g (including batteries) ◆For details, please refer to the catalog.
- Application/Performance example
- Please make use of it for daily work environment management and air quality measurement in homes, schools, and offices.
Automatic Gas Collection Device GSP-500FT
- overview
- <Specifications> - Setting Modes Timer Mode: Automatic stop at set time (1 minute to 30 hours) Fixed Volume Mode: Automatic stop at set volume (0.01 to 900L) - Flow Rate Range Timer Mode: 50 to 500 mL/min Fixed Volume Mode: 10 to 500 mL/min (For 10 to 49 mL/min, intermittent sampling at a suction flow rate of 50 mL/min) - Power Supply Two AA alkaline batteries or nickel-hydride batteries Dedicated lithium-ion rechargeable battery (optional) - Continuous Usage Time AA alkaline batteries: Approximately 20 hours (200 mL/min, 2 kPa, 25°C) Lithium-ion rechargeable battery (optional): Approximately 90 hours (200 mL/min, 2 kPa, 25°C) - Dimensions Approximately 80(W) × 40(D) × 126(H) mm - Weight Approximately 280g (including batteries) ◆ For more details, please refer to the catalog.
- Application/Performance example
- Please use it for daily work environment management and air quality measurement in homes, schools, and offices.
Automatic Gas Collection Device GSP-400FT
- overview
- <Specifications> Set flow rate range: 50–1000 mL/min Set mode: (Timer mode) automatically stops at set time, cumulative flow display (Fixed volume mode) automatically stops at set volume, suction time display Instantaneous and cumulative flow accuracy: 100–1000 mL/min: ±5% RD (±3% RD when calibrated) 50–99 mL/min: ±5 mL/min (not supported for specified calibration) Operating temperature and humidity range: (Temperature) 0–40°C (Humidity) 10–90% RH (without condensation) Power supply: 4 AA alkaline batteries or nickel-hydride batteries Continuous usage time: approximately 10 hours (1000 mL/min, no load at 20°C or above) AC power (using AC adapter), external battery (optional) External dimensions: approximately 150(W) × 75(D) × 100(H) mm Weight: approximately 500g (including batteries) ◆ For details, please refer to the catalog.
- Application/Performance example
- It is for sampling harmful air pollutants.
-
Membership (free) is required to view all content.
Already a Member? Log In Here