We have compiled a list of manufacturers, distributors, product information, reference prices, and rankings for Gas sampling device.
ipros is IPROS GMS IPROS One of the largest technical database sites in Japan that collects information on.

Gas sampling device - Company Ranking(3 companyies in total)

Last Updated: Aggregation Period:〜
This ranking is based on the number of page views on our site.

Company Name Featured Products
Product Image, Product Name, Price Range overview Application/Performance example
<Specifications> Instantaneous flow measurement range: 0 to 250 mL/min Setting modes: Timer mode (automatic suction stop at set time, cumulative flow display) Fixed volume mode (automatic suction stop at set volume, suction time display) Power supply: Alkaline dry batteries, AA size x 2 Continuous use: Approximately 5 hours (above 20°C) External dimensions: 80(W) x 40(D) x 140(H) mm Weight: 300g (including batteries) ◆For details, please refer to the catalog. Please make use of it for daily work environment management and air quality measurement in homes, schools, and offices.
<Specifications> - Setting Modes Timer Mode: Automatic stop at set time (1 minute to 30 hours) Fixed Volume Mode: Automatic stop at set volume (0.01 to 900L) - Flow Rate Range Timer Mode: 50 to 500 mL/min Fixed Volume Mode: 10 to 500 mL/min (For 10 to 49 mL/min, intermittent sampling at a suction flow rate of 50 mL/min) - Power Supply Two AA alkaline batteries or nickel-hydride batteries Dedicated lithium-ion rechargeable battery (optional) - Continuous Usage Time AA alkaline batteries: Approximately 20 hours (200 mL/min, 2 kPa, 25°C) Lithium-ion rechargeable battery (optional): Approximately 90 hours (200 mL/min, 2 kPa, 25°C) - Dimensions Approximately 80(W) × 40(D) × 126(H) mm - Weight Approximately 280g (including batteries) ◆ For more details, please refer to the catalog. Please use it for daily work environment management and air quality measurement in homes, schools, and offices.
<Specifications> Set flow rate range: 50–1000 mL/min Set mode: (Timer mode) automatically stops at set time, cumulative flow display (Fixed volume mode) automatically stops at set volume, suction time display Instantaneous and cumulative flow accuracy: 100–1000 mL/min: ±5% RD (±3% RD when calibrated) 50–99 mL/min: ±5 mL/min (not supported for specified calibration) Operating temperature and humidity range: (Temperature) 0–40°C (Humidity) 10–90% RH (without condensation) Power supply: 4 AA alkaline batteries or nickel-hydride batteries Continuous usage time: approximately 10 hours (1000 mL/min, no load at 20°C or above) AC power (using AC adapter), external battery (optional) External dimensions: approximately 150(W) × 75(D) × 100(H) mm Weight: approximately 500g (including batteries) ◆ For details, please refer to the catalog. It is for sampling harmful air pollutants.
---

---

---
  1. Featured Products
    Automatic Gas Sampling Device GSP-311FT (Intrinsic Safety Explosion-Proof Structure)Automatic Gas Sampling Device GSP-311FT (Intrinsic Safety Explosion-Proof Structure)
    overview
    <Specifications> Instantaneous flow measurement range: 0 to 250 mL/min Setting modes: Timer mode (automatic suction stop at set time, cumulative flow display) Fixed volume mode (automatic suction stop at set volume, suction time display) Power supply: Alkaline dry batteries, AA size x 2 Continuous use: Approximately 5 hours (above 20°C) External dimensions: 80(W) x 40(D) x 140(H) mm Weight: 300g (including batteries) ◆For details, please refer to the catalog.
    Application/Performance example
    Please make use of it for daily work environment management and air quality measurement in homes, schools, and offices.
    Automatic Gas Collection Device GSP-500FTAutomatic Gas Collection Device GSP-500FT
    overview
    <Specifications> - Setting Modes Timer Mode: Automatic stop at set time (1 minute to 30 hours) Fixed Volume Mode: Automatic stop at set volume (0.01 to 900L) - Flow Rate Range Timer Mode: 50 to 500 mL/min Fixed Volume Mode: 10 to 500 mL/min (For 10 to 49 mL/min, intermittent sampling at a suction flow rate of 50 mL/min) - Power Supply Two AA alkaline batteries or nickel-hydride batteries Dedicated lithium-ion rechargeable battery (optional) - Continuous Usage Time AA alkaline batteries: Approximately 20 hours (200 mL/min, 2 kPa, 25°C) Lithium-ion rechargeable battery (optional): Approximately 90 hours (200 mL/min, 2 kPa, 25°C) - Dimensions Approximately 80(W) × 40(D) × 126(H) mm - Weight Approximately 280g (including batteries) ◆ For more details, please refer to the catalog.
    Application/Performance example
    Please use it for daily work environment management and air quality measurement in homes, schools, and offices.
    Automatic Gas Collection Device GSP-400FTAutomatic Gas Collection Device GSP-400FT
    overview
    <Specifications> Set flow rate range: 50–1000 mL/min Set mode: (Timer mode) automatically stops at set time, cumulative flow display (Fixed volume mode) automatically stops at set volume, suction time display Instantaneous and cumulative flow accuracy: 100–1000 mL/min: ±5% RD (±3% RD when calibrated) 50–99 mL/min: ±5 mL/min (not supported for specified calibration) Operating temperature and humidity range: (Temperature) 0–40°C (Humidity) 10–90% RH (without condensation) Power supply: 4 AA alkaline batteries or nickel-hydride batteries Continuous usage time: approximately 10 hours (1000 mL/min, no load at 20°C or above) AC power (using AC adapter), external battery (optional) External dimensions: approximately 150(W) × 75(D) × 100(H) mm Weight: approximately 500g (including batteries) ◆ For details, please refer to the catalog.
    Application/Performance example
    It is for sampling harmful air pollutants.